Mini-Chillers and Ductless H2O mini-split fan coils
 

1source2buy is an authorized wholesale and retail Multiaqua distributor. If you need help planning a chiller system, press the sales help button below and we will assist you, or give us a call.

Also available are: mini-splits - spacepak high velocity

 
 

Multiaqua mini-chillers and heat pumps - R407c Refrigerant

Ultimate comfort control commonly used in large commercial spaces is now available for your residential or small commercial new construction, or renovation project. Now, you can control the climate of each room, or area in your home individually, even turning off areas that are not used at certain times of the day for energy savings. Zoned Multiaqua high efficiency mini-chilled water systems contain the highest efficiency scroll compressor and provide reliable individual room temperature control, superior energy savings and easy installation. Heating can be obtained by using either the heat-pump chiller, or by using a standard electric or gas water heater hooked in to the water loop, or a heat exchanger transferring the heat to the water loop by using a boiler. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request. 12-week lead time on 460 volt units. If ordering only one chiller with no fan coils, be sure to add the appropriate crate to the order too.

Multiaqua chillers
Chiller Model
BTUs
Tons
Voltage/Hz/Phase
Price
MAC036-1-N
36,000
3
208-230/50-60/1
Contact Us
MAC048-1-N
48,000
4
208-230/50-60/1
Contact Us
MAC060-1-N
60,000
5
208-230/50-60/1
Contact Us
MAC120-1-R407
120,000
10
208-230/50-60/1
Contact Us
MAC036-2-N 36,000 3 208-230/50-60/3 Contact Us
MAC048-2-N 48,000 4 208-230/50-60/3 Contact Us
MAC060-2-N 60,000 5 208-230/50-60/3 Contact Us
MAC120-2-R407
120,000
10
208-230/50-60/3
Contact Us
MAC060-3-N 60,000 5 380-460/50-60/3 Contact Us
MAC120-3-R407
120,000
10
380-460/50-60/3
Contact Us
Low Ambient Kit - - Operation to 0°F Contact Us
Heat Pump Model
BTUs
Tons
Voltage/Hz/Phase
Price
MACH-060-1
60,000
5
208-230/50-60/1
Contact Us
 
 
 

Chiller Information

Upgrade
Computer Rooms
Upgrade your current, or new construction comfort system to chilled water with individual room zones and realize increased comfort and energy savings over typical ducted air-conditioning systems. These systems have also had very good results in computer and server room cooling applications.
Low Outdoor Temperature
Warranty
A low-ambient kit is optional, to allow the chiller to cool in extreme cold outdoor temperatures.
Brand new mini-chiller or reverse-cycle mini-chiller heat-pump units come with a full 5 year manufacturer's warranty on the compressor and heat exchanger, and a 1 year warranty on all parts for installations in the USA.
Heating Option 1
Heating Option 2
Heating can be obtained by using a separate heat exchanger and using an electric or gas water heater, which can also be used for domestic hot water needs.
The NEW heat-pump version provides cooling and reverse-cycle heating, when needed, eliminating the need for an extra water heating source.
Accessories
Circulation Pump
All accessories, such as chilled-water fan coils, solenoid valves, thermostats, expansion tanks, KITEC hoses and fittings are available as well. Chillers have a built-in circulation pump rated for 50' maximum head pressure. If your system designs need more than this an optional add on in-line hydronic pump may be added in to the water loop to boost pressure.

Multiaqua Chilled Water Fan Coils - Multi Position

Multi-position Fan Coil. Mounts on wall, near floor, or on ceiling, pointing down horizontally. Cool/Heat versions are equipped with 24 volt terminal strips, so a wall mounted wired-in thermostat could be used. When ordering a quantity of -1- a crate will be needed for secure shipping. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.

Model#
Capacity
Volts
# Pipes
Price
CFFWA-04-1-U
1-Ton
230
2
Contact Us
CFFWA-06-1-U
1.5-Ton
230
2
Contact Us
CFFWA-08-1-U
2-Ton
230
2
Contact Us
CFFWA-12-1-U
3-Ton
230
2
Contact Us
CFFWA-16-1-U
4-Ton
230
2
Contact Us
CFFWA-20-1-U
5-Ton
230
2
Contact Us

 

Multiaqua Chilled Water Fan Coils - High Wall

High-wall mounted Fan Coil. Mounts on wall, near ceiling, pointing down horizontally. Includes wire-less infrared remote control for all functions. A full function electronic wired control is also available as an option. For more information or pricing, email us, or call sales at (813) 977-5286.. Full line catalogs are available upon request.

Model#
Capacity
Volts
# Pipes
Price
MHWW-09-H-1
8,057
230
2
Contact Us
MHWW-12-H-1
11,331
230
2
Contact Us
MHWW-18-H-1
17,023
230
2
Contact Us
MHWW-24-H-1
23,709
230
2
Contact Us
MHWW-36-H-1
35,900
230
2
Contact Us

 

Multiaqua Chilled Water Fan Coils - Ceiling Concealed Hideaway

Ceiling concealed hideaway Fan Coil. Mounts in closet, ducted right out in to the area, or concealed above the ceiling if a housing is made around the unit. Includes 24 volt terminals and relays for hooking up a wired-in wall mounted thermostat. 208-230 volts except as noted. When ordering a quantity of -1- a crate will be needed for secure shipping. For more information or pricing, email us, or call sales at (813) 977-5286.. Full line catalogs are available upon request.

Model#
Capacity
Volts available
Heat Available Kw
# Pipes
Price
MHCCW-04
1-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
MHCCW-06
1.5-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
MHCCW-08
2-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
MHCCW-10
2.5-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
MHCCW-12
3-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
MHNCCW-04
1-Ton
115 or 230
Hot Water
4 Contact Us
MHNCCW-06
1.5-Ton
115 or 230
Hot Water
4 Contact Us
MHNCCW-08
2-Ton
115 or 230
Hot Water
4 Contact Us
MHNCCW-10
2.5-Ton
115 or 230
Hot Water
4 Contact Us
MHNCCW-12
3-Ton
115 or 230
Hot Water
4 Contact Us

 

Multiaqua Chilled Water Fan Coils - Ducted

The CWA2 and CWA4 water cooled/heated ducted fan coils for multi-position applications in closet, attic, garage, or basement. Electric heat strips are optional on all sizes and are indicated as the -XX part of the model number. Just replace -XX with the heat strip size needed. Upflow, horizontal right to left and convertable to left to right. 208-240 volts AC, 60 Hz, 1 phase. just like a typical ducted air-handler. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.

Model#
Capacity Tons
Electric Heat Options
Filter Size
Fan Speeds # Pipes
18CWA2-XX 1.5 0, 5, 8, 10 KW 16x20x1 3 2
24CWA2-XX 2.0 0, 5, 8, 10 KW 16x20x1 3 2
36CWA2-XX
3.0
0, 5, 8, 10 KW
20x20x1
3 2
48CWA2-XX
4.0
0, 5, 8, 10 KW
20x25x1
3 2
60CWA2-XX
5.0
0, 5, 8, 10 KW
20x25x1
3 2
24CWA4-HW 2.0 Hot Water 16x20x1 3 4
36CWA4-HW
3.0
Hot Water
20x20x1
3 4
48CWA4-HW
4.0
Hot Water
20x25x1
3 4
60CWA4-HW
5.0
Hot Water
20x25x1
3 4

 

Aerosys H2O - Ducted

Units are factory new. 115 or 230 Volts. Chilled Water ducted fan coils. The DCW Series of chilled water air handlers are designed to operate with centrally supplied chilled water source. Units are rated for use with 42ºF, 45ºF and 48ºF entering water temperatures in the cooling mode. These systems can also be used as a heating system when supplied with hot water instead of the chilled water. Units are rated for use with inlet hot water temperatures from 120ºF to 180ºF. These units are not recommended for leaving air temperatures over 140ºF. Low RPM blowers provide quiet operation, Multi 3-speed motors are field selectable for the application requirements, Powder coated cabinet for a durable finish. For more information or pricing, email us, or call sales at (813) 977-5286.

No Image Available
Model
Cooling Capacity 45° Water
Heating Capacity 140° Water
Dimensions HxWxD
Price
Purchase
DCW-20
22,000
36,000
29x24x14
$569.00
Quantity Desired:
DCW-26
27,000
45,000
33x24x14
$600.00
Quantity Desired:
DCW-32
30,000
54,300
34.75x29x15
$652.00
Quantity Desired:
 

Chiller Accessories

These are the common installation accessories for a chiller system. For more information or pricing, email us, or call sales at (813) 977-5286.. Full line catalogs are available upon request.

Part#
Description
Price Purchase
MZV524E-T
Honeywell Sparco 1/2" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $121
Quantity Desired:
MZV525E-T
Honeywell Sparco 3/4" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $121
Quantity Desired:
MZV526E-T
Honeywell Sparco 1" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $130
Quantity Desired:
1500/1" Amtrol Expansion Tank Assembly Containing #15 Extrol tank, #700 air vent, #443 air purger 1". Use 1" or thicker ARMAFLEX insulation sheet. Page 3 Product Data Sheet $115
Quantity Desired:
WX202H 20 Gallon Storage Tank. Made exclusively for Multiaqua. Horizontal tank space saver model with two 1" NPT fittings for inlet and outlet purposes. Bladder has also been removed. Use 1" or thicker ARMAFLEX insulation sheet. Page 1 Product Data Sheet $286
Quantity Desired:
WX422H 42 Gallon Storage Tank. Made exclusively for Multiaqua. Horizontal tank space saver model with two 1.25" FNPT fittings for inlet and outlet purposes and 1" NPT plug. Bladder has also been removed. Use 1" or thicker ARMAFLEX insulation sheet. Page 2 Product Data Sheet $665
Quantity Desired:
D146M1032 Honeywell Braukman 3/4" Bypass Valve w/ dial adjustment Page 4 Product Data Sheet $159
Quantity Desired:
D146M1040 Honeywell Braukman 1 1/4" Bypass Valve w/ dial adjustment Page 4 Product Data Sheet $223
Quantity Desired:
T513 Erie Rotary Heat/Cool, 3 speed fan, Ht/Off/CL 24 Volt $80
Quantity Desired:
SSP-1 1/2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $511
Quantity Desired:
1MS1E4CO 1 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $555
Quantity Desired:
1MS1F4BO 1-1/2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $629
Quantity Desired:
1MS1G2AO 2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $695
Quantity Desired:

 
 
 

Multiaqua Mini-Chiller Benefits

No Refrigerant Handling
No Ductwork
No need to charge with refrigerant. The closed refrigerant system does away with the need for installation technicians that are certified to handle refrigerants. Because there are no refrigerant lines, installation costs are lower vs standard split systems. Cooling and heating with Multiaqua means running small, flexible, water pipes into the space within the walls, directly to the indoor chilled-water fan coils, without giving up hundreds of square feet of useable or living space to ductwork.
0% Duct Loss
Adjustable Water Temperature
Because insulated water lines carry the cooling capacity in the system. This is a more efficient unit delivering rated capacity to all of the conditioned spaces day after day.
Chillers are preset with water temperature at 44°F and can be adjusted down to 40°F water temperature, or up higher if desired.
Zoned Cooling And Heating
Ultra High Efficiency
With Multiaqua chilled water fan coils, you condition only the spaces you designate -not the whole house as opposed to a traditional central system. This fact allows for diversity and load shifting (For example, 10 tons of indoor coils may be hooked up to a 5 Ton chiller.) when doing load and sizing calculations, initially reducing installed cost as well as operating costs for years to come.
The Multiaqua Chiller contains the Copeland Compliant Scroll, a 20 CHEER compressor; simply the most efficient, quiet, reliable compressor available. If you already have a chilled water system and just need to add on, or replace current fan coils, the Multiaqua fan coils will work.
Fan Coils
.
The Multiaqua Non-ducted Fan Coils -  have worldwide recognition for quiet, reliable operation and have a reputation for sleek, seamless design. These chilled water fan coils can be operated from a central thermostat or can have individual controls, infrared remotes or hard-wired controls. Sizes are available from 9,000 BTU to 55,000 BTU. .

What You Will Need

Multiaqua Chiller/SpacePak Chiller
Fan Coils
The heart of the chilled water system. This is where the cooling of the water takes place. In the heat-pump version, heating also takes place inside this unit. The chiller can be located a distance away from the main structure to reduce sound levels inside. Just be sure to accurately account for the extra pressure loss due to using longer runs of pipe. The circulation pump is also inside this unit. Be sure the use the proper percentage of glycol in the water loop to prevent freezing The wall mounted fan coils come standard with a wireless remote control for each unit. From the remote, you can control temperature, fan speed, vane direction and cooling/off/heat mode. There are also universal mount fan coils that can mount low on the wall, near the floor, or up on the ceiling. Also, the ceiling concealed hide-away fan coil is perfect for installing in a closet, or dropped ceiling. SpacePak high velocity fan coils have been very successful with chiller installations. If you need a different type of fan coil, other than what is in the Multiaqua line, other brands will work with this system too. Just let us know what you are looking for and we will present you with all the available options in fan coils.
Tubing
Solenoid Valves
Use either copper tubing with insulation, or composite tubing, such as Vanguard PEX, or KITEC with a built-in vapor barrier. Just remember that your supply and return tubing needs to be insulated.
These electronically control the flow of cooled or heated liquid solution to each fan coil. Each fan coil needs to have an electronic solenoid valve. 3-way solenoid valves are preferred over two way valves, because you can keep system pressures fairly constant by sending water to the return line when the fan coil is not calling for cool or heat.
Bypass Valve
Expansion Tank
This is used to relieve system pressure from the supply to the return, as system fan coil valves are opened and closed. This valve should be installed near the beginning of the water loop, close to the chiller. In addition to a bypass valve 3-way solenoid valves are recommended over 2-way valves.
Used to compensate for the expansion and contraction of liquid in the system. The included air-scoop eliminates air entrained in the system. In addition to the air removal in the expansion tank, you will also need to be certain that you bleed the air from all the bleeder valves in the entire system during the initial start-up, or pump failure will occur.
Storage Tank
.
This is used in systems that will contain a total of less than 25 gallons of liquid solution. The tank prevents rapid cycling of the compressor. It must also be insulated. Use 25 gallons minimum for 3 and 4-ton systems and use 25-30 gallons of storage per 5-tons. .